The device is a resistance thermometer transmitter, from which 24VDC digital inputs / outputs can be used to acquire scaled and calibrated data. It can be used with any industrial controller with 24VDC input and semiconductor 24VDC digital output. Only one digital output (which can be used for multiple transmitters) and one digital input per transmitter are required to be able to use it.
Technical data:
-
IP enclosure class: IP65
-
Supply voltage: 24VDC via CLK channel
-
Operating temperature: -40°C - +80°C
-
Other properties:
-
Transmission of 16 bit measured values in digital format
-
Data transfer is protected by a 4 bit error detection code (CRC4-CCITT)
-
Multiple temperature sensor options
-
Digital filtering
-
The transmitter family has the following types
Transmitter type |
|
Received temperature sensor |
Measuring range |
Output |
Linearizing |
transm. error |
||||||||||
|
|
|
|
|
Min |
Max |
resolution |
polynomial |
max |
|||||||
HS10 |
R |
PT100 |
|
PT100 RTD |
-100˚C |
240˚C |
0,01˚C |
ITS90 IEC751 |
±0,5˚C |
|||||||
|
|
|
NI100 |
|
NI100 RTD |
-60˚C |
140˚C |
0,01˚C |
DIN43760 |
±0,5˚C |
||||||
|
T |
|
J |
|
type J thermocouple |
-210˚C |
1200˚C |
0,1˚C |
ITS90 |
±2˚C |
||||||
|
|
|
K |
|
type K thermocouple |
-200˚C |
1372˚C |
0,1˚C |
ITS90 |
±2˚C |
||||||
|
|
|
T |
|
type T thermocouple |
-200˚C |
400˚C |
0,1˚C |
ITS90 |
±2˚C |
||||||
|
|
|
E |
|
type E thermocouple |
-200˚C |
1000˚C |
0,1˚C |
ITS90 |
±2˚C |
||||||
|
|
|
N |
|
type N thermocouple |
-200˚C |
1300˚C |
0,1˚C |
ITS90 |
±2˚C |
||||||
|
|
|
B |
|
type B thermocouple |
250˚C |
1820˚C |
0,25˚C |
ITS90 |
±5˚C |
||||||
|
|
|
R |
|
type R thermocouple |
-50˚C |
1768˚C |
0,2˚C |
ITS90 |
±5˚C |
||||||
|
|
|
S |
|
type S thermocouple |
-50˚C |
1768˚C |
0,2˚C |
ITS90 |
±5˚C |
||||||
|
U |
|
1 |
|
Analog temperature sensor (TC1047A) |
-40˚C |
50˚C |
0,01˚C |
- |
±2˚C |
||||||
|
|
|
2 |
|
Differential analog input |
-256mV |
256mV |
16bit |
- |
0,10% |
||||||
|
|
|
3 |
|
Differential analog input |
-1024mV |
1024mV |
16bit |
- |
0,10% |
||||||
|
|
|
4 |
|
Differential analog input |
-2048mV |
2048mV |
16bit |
- |
0,10% |
||||||
|
B |
|
MC |
|
Internal semiconductor based temp. sensor |
-40˚C |
80˚C |
0,01˚C |
- |
±2˚C |
||||||
|
|
|
AD |
|
Internal semiconductor based temp. sensor |
-40˚C |
80˚C |
0,01˚C |
- |
±0,5˚C |